VACUUM WATER DEAERATION VWD

VACUUM WATER DEAERATION

The Vacuum Water Degassing (VWD) deaerates water down to a residual oxygen concentration below 10 ppb. Optionally the water can be cooled down, filtered or sterilized with ultraviolet light. The function of the unit can be monitored and documented by an in-line oxygen analyzer at the outlet of the unit.

The process is employed in the brewing, beverage, food and chemical-pharmaceutical industries, wherever water with lowest oxygen content is required to assure high product quality and stability. The system is characterized by high operational reliability, low CO2 and energy consumption.

ADVANTAGES AND FUNCTIONS

TECHNICAL DESCRIPTION

The water is distributed homogeneously to the structured packing at the top of the column. The CO2 is fed in at the bottom of the column. The water slowly flows downwards through the structured packing in counter current flow to the CO2.

A long and intensive contact between water and stripping gas is ensured by the high-performance structured packing. CO2 is dissolved in the water up to a level of 0.2 g/l and at the same time suppresses the oxygen. The operation of the column under vacuum, with a pressure about 80 mbar, reduces the partial pressure of gas. Low oxygen values and CO2-consumption are reached. Optionally, nitrogen can be used as stripping gas. The deaerated water is pumped out of the bottom of the column with a frequency-controlled pump. Optionally the water can be cooled down in a plate heat exchanger by glycol or ammonia.

Sensors for oxygen, level, flow and temperature monitor the proper functioning of the system.
The unit can be controlled by a local PLC with a touch panel or by a process control system.
Designed for high hygienic standards, all common cleaning agents in the beverage and chemical-pharmaceutical industry can be used for CIP cleaning.

TECHNICAL SPECIFICATION

 
Capacity25 to 1,000 hl/h / 2.5 to 100 m3/h
Residual oxygen content< 10 ppb / 0.01 ppm
CO2 consumption0.3 g/l
CO2 supplymin. 6 barg / ≥99.98% purity
Cooling mediaglycol or ammonia

 

© 2019 NH-TECH.CO.TH All rights reserved.

COLD WATER DEAERATION CWD

COLD WATER DEAERATION

The Cold Water Deaeration (CWD) deaerates water down to a residual oxygen concentration below 50 ppb. At the same time the water is saturated with 2 g/l CO2. Optionally it can be cooled down, filtered or sterilized with ultraviolet light. The function of the unit can be monitored and documented by an in-line oxygen analyzer at the outlet of the unit.

The process is employed in the brewing, beverage, food and chemical-pharmaceutical industries, wherever water with low oxygen content is required to assure high product quality and stability. The system is characterized by high operational reliability, simple functionality and low investments. Due to the carbonization of water, the unit is especially suitable for the production of carbonated beverages.

ADVANTAGES AND FUNCTIONS

TECHNICAL DESCRIPTION

The water is distributed homogeneously to the structured packing at the top of the column. The CO2 is fed in at the bottom of the column. The water slowly flows downwards through the structured packing in counter current flow to the CO2.

A long and intensive contact between water and stripping gas is ensured by the high-performance structured packing. CO2 is dissolved in the water up to a level of 2.0 g/l and at the same time suppresses the oxygen. Optionally, nitrogen can be used as stripping gas. The deaerated water is pumped out of the bottom of the column with a frequency controlled pump. Optionally the water can be cooled down in a plate heat exchanger by glycol or ammonia.

Sensors for oxygen, level, flow and temperature monitor the proper functioning of the system.
The unit can be controlled by a local PLC with a touch panel or by a process control system.
Designed for high hygienic standards, all common cleaning agents in the beverage and chemical-pharmaceutical industry can be used for CIP cleaning.

TECHNICAL SPECIFICATION

Capacity25 to 1,000 hl/h / 2.5 to 100 m3/h
Residual oxygen content< 50 ppb / 0.05 ppm
CO2 consumption2.4 g/l
CO2 supply6 barg / ≥99.98% purity
Cooling mediaglycol or ammonia

© 2019 NH-TECH.CO.TH All rights reserved.

DEGASSING

DEGASSING OF LIQUIDS

Oxygen – known in breweries as the greatest enemy of beer. It leads to oxidation, changes the aroma profile of the beer negatively and impairs its shelf life. It is therefore important to prevent oxygen from getting into the finished beer at all stages. However, this is only possible if the water with which the beer comes into contact or with which the beer is blended is also oxygen-free. For this reason, the water used must always be reliably degassed. The possibilities for this are manifold, and the results are correspondingly manifold. Take a look at the different solutions we have developed over the years and which are used by many customers worldwide.

OUR SOLUTIONS FOR WATER DEGASSING

The search for the right water degassing system can be difficult. If you have any questions or would like advice, our specialists will be happy to assist you.